Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Acad Radiol ; 26(5): 626-631, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30097402

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this paper is to describe the integration of a commercial chest CT computer-aided detection (CAD) system into the clinical radiology reporting workflow and perform an initial investigation of its impact on radiologist efficiency. It seeks to complement research into CAD sensitivity and specificity of stand-alone systems, by focusing on report generation time when the CAD is integrated into the clinical workflow. MATERIALS AND METHODS: A commercial chest CT CAD software that provides automated detection and measurement of lung nodules, ascending and descending aorta, and pleural effusion was integrated with a commercial radiology report dictation application. The CAD system automatically prepopulated a radiology report template, thus offering the potential for increased efficiency. The integrated system was evaluated using 40 scans from a publicly available lung nodule database. Each scan was read using two methods: (1) without CAD analytics, i.e., manually populated report with measurements using electronic calipers, and (2) with CAD analytics to prepopulate the report for reader review and editing. Three radiologists participated as readers in this study. RESULTS: CAD assistance reduced reading times by 7%-44%, relative to the conventional manual method, for the three radiologists from opening of the case to signing of the final report. CONCLUSION: This study provides an investigation of the impact of CAD and measurement on chest CTs within a clinical reporting workflow. Prepopulation of a report with automated nodule and aorta measurements yielded substantial time savings relative to manual measurement and entry.


Assuntos
Eficiência , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Radiologia/organização & administração , Nódulo Pulmonar Solitário/diagnóstico por imagem , Humanos , Radiografia Torácica , Sensibilidade e Especificidade , Software , Fatores de Tempo , Tomografia Computadorizada por Raios X , Fluxo de Trabalho
3.
Eur Radiol ; 22(7): 1547-55, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22466511

RESUMO

OBJECTIVES: To investigate volumetric and density changes in the ipsilateral and contralateral lobes following volume reduction of an emphysematous target lobe. METHODS: The study included 289 subjects with heterogeneous emphysema, who underwent bronchoscopic volume reduction of the most diseased lobe with endobronchial valves and 132 untreated controls. Lobar volume and low-attenuation relative area (RA) changes post-procedure were measured from computed tomography images. Regression analysis (Spearman's rho) was performed to test the association between change in the target lobe volume and changes in volume and density variables in the other lobes. RESULTS: The target lobe volume at full inspiration in the treatment group had a mean reduction of -0.45 L (SE = 0.034, P < 0.0001), and was associated with volume increases in the ipsilateral lobe (rho = -0.68, P < 0.0001) and contralateral lung (rho = -0.16, P = 0.006), and overall reductions in expiratory RA (rho = 0.31, P < 0.0001) and residual volume (RV)/total lung capacity (TLC) (rho = 0.13, P = 0.03). CONCLUSIONS: When the volume of an emphysematous target lobe is reduced, the volume is redistributed primarily to the ipsilateral lobe, with an overall reduction. Image-based changes in lobar volumes and densities indicate that target lobe volume reduction is associated with statistically significant overall reductions in air trapping, consistent with expansion of the healthier lung. KEY POINTS: Computed tomography allows assessment of the treatment of emphysema with endobronchial valves. • Endobronchial valves can reduce the volume of an emphysematous lung lobe. • Compensatory expansion is greater in ipsilateral lobes than in the contralateral lung. • Reduced air trapping is measurable by RV/TLC and smaller low attenuation area.


Assuntos
Broncoscopia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Acad Radiol ; 17(3): 316-22, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20004119

RESUMO

RATIONALE AND OBJECTIVES: Lung and lobar volume measurements from computed tomographic (CT) imaging are being used in clinical trials to assess new minimally invasive emphysema treatments aiming to reduce lung volumes. Establishing the reproducibility of lung volume measurements is important if they are to be accepted as treatment planning and outcome variables. The aims of this study were to (1) investigate the correlation between lung volumes assessed on CT imaging and on pulmonary function testing (PFT), (2) compare the two methods' reproducibility, and (3) assess the reproducibility of CT lobar volumes. MATERIALS AND METHODS: CT imaging and body plethysmography were performed at baseline and after a 9-month interval in multicenter emphysema treatment trials. Lung volumes were measured at total lung capacity (TLC) and at residual volume (RV). Lobar volumes were measured on CT imaging using a semiautomated technique. The correlations between CT and PFT volumes were computed for 486 subjects at baseline. Reproducibility was assessed in terms of the intraclass correlation coefficient (ICC) for 126 subjects from the control group at TLC and 120 subjects at RV. RESULTS: Correlations between CT and PFT lung volumes were 0.86 at TLC and 0.67 at RV. At TLC, the ICCs were 0.943 for CT imaging and 0.814 for PFT. At RV, the ICCs were 0.886 for CT imaging and 0.683 for PFT. CT lobar volumes showed good reproducibility (all P values < .05). CONCLUSION: CT lung and lobar volume measurements could be captured in a multicenter trial setting with high reproducibility and were highly correlated with those obtained on PFT. CT imaging showed significantly better reproducibility than PFT between interval lung volume measurements, offering the potential for designing emphysema treatment trials involving fewer subjects.


Assuntos
Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Acad Radiol ; 15(9): 1173-80, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18692759

RESUMO

RATIONALE AND OBJECTIVES: Segmentation of lungs using high-resolution computer tomographic images in the setting of diffuse lung diseases is a major challenge in medical image analysis. Threshold-based techniques tend to leave out lung regions that have increased attenuation, such as in the presence of interstitial lung disease. In contrast, streak artifacts can cause the lung segmentation to "leak" into the chest wall. The purpose of this work was to perform segmentation of the lungs using a technique that selects an optimal threshold for a given patient by comparing the curvature of the lung boundary to that of the ribs. METHODS: Our automated technique goes beyond fixed threshold-based approaches to include lung boundary curvature features. One would expect the curvature of the ribs and the curvature of the lung boundary around the ribs to be very close. Initially, the ribs are segmented by applying a threshold algorithm followed by morphologic operations. The lung segmentation scheme uses a multithreshold iterative approach. The threshold value is verified until the curvature of the ribs and the curvature of the lung boundary are closely matched. The curve of the ribs is represented using polynomial interpolation, and the lung boundary is matched in such a way that there is minimal deviation from this representation. Performance of this technique was compared with conventional (fixed threshold) lung segmentation techniques on 25 subjects using a volumetric overlap fraction measure. RESULTS: The performance of the rib segmentation technique was significantly different from conventional techniques with an average higher mean volumetric overlap fraction of about 5%. CONCLUSIONS: The technique described here allows for accurate quantification of volumetric computed tomography and more advanced segmentation of abnormal areas.


Assuntos
Pulmão/diagnóstico por imagem , Costelas/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Pulmão/anatomia & histologia , Pneumopatias/diagnóstico por imagem
6.
Comput Med Imaging Graph ; 31(4-5): 332-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17418527

RESUMO

Computer-aided diagnosis (CAD) technology is becoming an important tool to assess treatment response in clinical trials. However, CAD software alone is not sufficient to conduct an imaging-based clinical trial. There are a number of architectural requirements such as image receive (from multiple field sites), a database for storing quantitative measures, and data mining and reporting capabilities. In this paper we describe the architectural requirements to incorporate CAD into clinical trials and illustrate their functionality in therapeutic trials for emphysema.


Assuntos
Ensaios Clínicos como Assunto , Sistemas Computacionais , Diagnóstico por Computador/estatística & dados numéricos , Humanos , Avaliação de Resultados em Cuidados de Saúde , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/terapia , Radiografia , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA